Mechanical Tissue Ablation with Focused Ultrasound
Noninvasive Surgery Method Using Nonlinear Ultrasound Pulses
|
Videos: Boiling Histotripsy for Focal Therapy in Prostate
|
|
|
A collaborative team at APL-UW's Center for Industrial and Medical Ultrasound, with UW researchers and high-intensity focused ultrasound experts at Moscow State University are developing a technology to improve ultrasound treatment of prostate tumors. The team has built a prototype device to perform pre-clinical feasibility studies. It uses boiling histotripsy to mechanically liquefy tissue at the ultrasound focus rather than thermally ablating it.
|
|
|
|
Videos: (1) Method, Mechanisms, Instruments + (2) Clinical Applications
|
|
|
|
|
|
|
Boiling Histotripsy |
Clinical Applications |
|
|
Our method has important advantages over thermal high intensity focused ultrasound treatments. We can control lesion location and size precisely and spare critical structures such as blood vessels.
In terms of clinical applications, the range is quite broad. It basically can be applied to any treatment that requires any form of tissue ablation.
|
|
Presentations
|
|
|
Transcutaneous boiling histotripsy ablation of the kidney in an in vivo porcine model, by Vera Khokhlova, delivered at the 5th International Symposium of Focused Ultrasound in Bethesda, MD, 29 August 1 September 2016.
|
|
Focused ultrasound tissue disintegration: Mechanisms and applications to noninvasive surgery, by Adam Maxwell, delivered at the LIMU Seminar, 9 October 2015.
|
|
Research Team + Collaborators
|
|
|
|
Boiling Histotripsy Method
|
|
|
Boiling histotripsy (BH) is a novel approach in high intensity focused ultrasound (HIFU) therapy to mechanically destroy remote target sites within a small focal region without damaging intervening tissues. BH utilizes sequences of millisecond-duration HIFU pulses with high-amplitude shocks that form at the focus by nonlinear propagation effects. Due to strong attenuation of the ultrasound energy at the shocks, these nonlinear waves rapidly heat tissue and generate millimeter-sized boiling bubbles at the focus within each pulse. Then the further interaction of subsequent shocks with the vapor cavity causes tissue disintegration into subcellular debris through the acoustic atomization mechanism.
|
|
The method was proposed at APL-UW in collaboration with Moscow State University (Russia) and now is being evaluated for various clinical applications. It has particular promise because of its important clinical advantages: the treatment of tissue volumes can be accelerated while sparing adjacent structures and not injuring intervening tissues; it generates precisely controlled mechanical lesions with sharp margins; the method can be implemented in existing clinical systems; and it can be used with real-time ultrasound imaging for targeting, guidance, and evaluation of outcomes. In addition, compared to thermal ablation, BH may lead to faster resorption of the liquefied lesion contents.
|
|
Physical Mechanisms of Tissue Liquefaction
|
|
|
In boiling histotripsy, localized tissue volume at the focus of a HIFU beam is disintegrated into submicron-sized fragments. It was proposed that the physical mechanism of such fractionation is ultrasonic atomization, or the emission of a fine spray of droplets. Ultrasonic atomization is a well-known phenomenon used commercially in air humidifiers and medical nebulizers. In BH, this phenomenon occurs when a HIFU beam encounters the millimeter-sized vapor cavity (a tissue/vapor interface) generated at the focus by shock-wave superheating of tissue, i.e., boiling.
|
|
The radiation force from the beam induces a bulge at the tissuevapor interface resulting in focusing of the reflected waves and generation of many cavitation bubbles in the bulge. Then cavitation and unstable capillary waves cause fine droplets to pinch off from the surface into the vapor bubble, disintegrating the tissue.
|
|
Instruments
|
|
|
Boiling histotripsy is performed with highly focused ultrasound transducers that concentrate acoustic pressure down to a small focal region at the target site. The transducers are piezoelectric, such that when a cyclic voltage is applied to the material, it expands and contracts to produce sinusoidal ultrasound waves that distort into shock waves near the focus due to nonlinear propagation effects.
|
|
The transducer voltage is generated by a high-power pulse generator. We have worked with a clinical system that is capable of generating shock-wave fields at the focus. Many focused histotripsy transducers have been designed, fabricated, and tested by our lab. We also designed a multi-element array for an ultrasound-guided BH pre-clinical system. Our research is focused on improving the capabilities of transducers and electronics to allow boiling histotripsy to be used in a broad range of applications.
|
|
Histological + Biochemical Evaluation of Outcomes
|
|
|
Boiling histotripsy can result in a range of bioeffects (mechanical with and without a thermal component). Single and volumetric lesions have been evaluated using a multimodal approach to determine the extent of mechanical disruption and the presence of a thermal component. Gross evaluation of bisected lesions, gave an idea of the liquidity of lesion contents and a qualitative evaluation of the thermal component.
|
|
Biochemical analysis enabled a quantitative evaluation of the thermal component. Histology and transmission electron microscopy (TEM) was used to evaluate the extent of the homogenization and the extent of lesion borders. The multimodal evaluation suggests that the degree of mechanical tissue disruption and heat generated in BH lesions could be tailored to the targeted clinical application.
|
|
|
Axial cross sections of BH lesions created in ex vivo bovine liver tissue: (a) liquid, (b) paste, and (c) vacuolated thermal. Each lesion type is illustrated by (i) a representative photograph and histologic images of consecutive frozen sections stained with (ii) H&E or (iii) NADH-d. The liquid and paste lesions are clearly demarcated in both H&E- and NADH-stained sections as tissue lacking cellular structure (a, b). Thermal damage is present in some areas of the paste lesion (b), but absent in the liquid lesion (a). The vacuolated thermal (c) lesion is characterized by the absence of NADH-d stain. Scale bar represents 2 mm.
|
|
Clinical Applications
|
|
|
Boiling histotripsy provides the ability to non-invasively fractionate unwanted soft tissue into sub-micron slurry while targeting and monitoring the procedure with ultrasound imaging. Unlike other forms of ablation, such as radio-frequency or cryoablation, boiling histotripsy is not affected by the 'heat sink effect' in highly perfused tissue, and is not limited by the size of the area to be treated. Further, connective tissue structures, such as blood vessels, biliary structures, or organ membranes were shown to be more resistant to boiling histotripsy damage than cells. This tissue selectivity allows treatment of areas immediately adjacent to large blood vessels or other critical structures.
|
|
Boiling histotripsy lesions generated in the cortex of a procine kidney and example of real-time ultrasound imaging of the treatment.
|
|
|
|
|
|
Video
|
Taken together, the characteristics of boiling histotripsy make it a very promising technology for a number of clinical applications, most importantly ablation of benign and malignant tumors, including liver, kidney, prostate and pancreas tumors. In the case of cancer tumors, the collection of fractionated (but not thermally damaged) tumor debris produced by the treatment, as well as the release of pro-inflammatory cytokines, may also stimulate activation and proliferation of tumor-specific T lymphocytes. If enhanced by additional immunotherapeutic interventions, this systemic anti-tumor immune response may potentially lead to the regression of distant metastases, and is currently the subject of pre-clinical studies by our group and others.
|
|
The hypothesized mechanism behind systemic anti-tumor immune response triggered by boiling histotripsy.
|
|
The Immune Response to Boiling Histotripsy Ablation of Renal Carcinoma, A presentation given by George Schade at the 5th International Symposium on Focused Ultrasound, 2016
|
|
|
|
|
Another promising application of boiling histotripsy is the management of large, soft tissue hematomas. Large intra-abdominal, retroperitoneal, and intramuscular hematomas are common consequences of sharp and blunt trauma and postsurgical bleeds. These often threaten organ failure, compartment syndrome, or spontaneous infection. Current therapy options include surgical evacuation and installation of indwelling drains that are not effective due to the viscosity of the organized hematoma. We have demonstrated that boiling histotripsy allows rapid (within 1520 minutes) liquifaction of large volumes of gelatinous hematoma. The liquid can then be aspirated with a fine needle, relieving the pressure on the surrounding tissues and organs.
|
|
Ultrasound image (left) of fine needle aspiration of a large blood clot liquefied by boiling histotripsy. The same sample is shown bisected on the right.
|
|
|
|
|
The ability to spare collagen rich structures such as blood vessels has another potential application. A promise of tissue engineering is to develop tissue and organ substitutes that replace diseased or injured tissue and organs. Suitable replacement tissues require scaffolds to provide three-dimensional support with an appropriate mechanical and biological environment to promote tissue neogenesis. The complex architecture of native tissue has been hard to recreate in the lab setting. The use of mammalian biological scaffolds could establish a foundation on which functional replacement of whole organs and complex tissues could be developed. Decellularization is the process by which the cellular material of an organ/tissue is removed. Current decellularization techniques are a lengthy process and can result in chemical alterations to the matrix. BH could potentially be used to decellularize organs for tissue engineering and regenerative medicine applications.
|
|
Area of bovine liver liquified with boiling histotripsy. Note the network of blood vessels and biliary structures that remained intact.
|
|
U.S. Patents
|
 |
|
Boiling histotripsy methods and systems for uniform volumetric ablation of an object by high-intensity focused ultrasound waves with shocks Patent Number: 12,157,018 An example method includes generating an acoustic ultrasound wave that is focused at a focal point. The method further includes sequentially directing the focal point upon distinct portions of an object to form respective shock waves at the distinct portions of the object. The method further includes, via the respective shock waves, causing the distinct portions of the object to boil and form respective vapor cavities. The method further includes causing substantially uniform ablation of a region of the object that comprises the distinct portions. The substantially uniform ablation is caused via interaction of the respective shock waves with the respective vapor cavities. An example ablation system and an example non-transitory computer-readable medium, both related to the example method, are also disclosed. |
|
3 Dec 2024
|
|
 |
 |
|
Transrectal Ultrasound Probe for Boiling Histotripsy Ablation of Prostate, and Associated Systems and Methods Patent Number: 11,896,853 Inventors: V. Khokhlova, P. Rosnitskiy (Seattle), P.V. Yuldashev (Moscow), T.D. Khokhlova (Seattle), O. Sapozhnikov, and G.R. Schade (Seattle) |
|
13 Feb 2024
|
|
 |
 |
|
MRI-Feedback Control of Ultrasound Based Mechanical Fractionation of Biological Tissue Patent Number: 11,224,356 Disclosed herein are example embodiments of devices, systems, and methods for mechanical fractionation of biological tissue using magnetic resonance imaging (MRI) feedback control. The examples may involve displaying an image representing first MRI data corresponding to biological tissue, and receiving input identifying one or more target regions of the biological tissue to be mechanically fractionated via exposure to first ultrasound waves. The examples may further involve applying the first ultrasound waves and, contemporaneous to or after applying the first ultrasound waves, acquiring second MRI data corresponding to the biological tissue. The examples may also involve determining, based on the second MRI data, one or more second parameters for applying second ultrasound waves to the biological tissue, and applying the second ultrasound waves to the biological tissue according to the one or more second parameters. |
|
18 Jan 2022
|
|
 |
 |
|
Histotripsy Treatment of Hematoma Patent Number: 10,702,719 A rapid, definitive intervention aiming at evacuation of the space-occupying hematoma would reduce pain, improve function, and avoid long term sequelae. Ultrasound is known to promote intravascular clot breakdown, as both a standalone procedure and used in conjunction with thrombolytic drugs and/or microbubbles. In-vitro and in-vivo studies have been conducted over the years, and acoustic cavitation is widely accepted as the dominant mechanism for mechanical disruption of the clot integrity and partial or complete recanalization of the vessel. Recently, a technique termed histotripsy that employs high-intensity focused ultrasound (HIFU) has been demonstrated to dissolve large in vitro and in vivo vascular clots without thrombolytic drugs within 1.5-5 minutes into debris 98% of which were smaller than 5 microns. However, this approach cannot be applied to the large extravascular hematomas due to their large volume (20-50 cc's) compared to intravascular clots, which necessitates much higher thrombolysis rates to complete the treatment within clinically relevant times (.about.15-20 minutes). |
|
7 Jul 2020
|
|
 |
 |
|
Method and System for MRI-based Targeting, Monitoring, and Quantification of Thermal and Mechanical Bioeffects in Tissue Induced by High Intensity Focused Ultrasound
Patent Number: 10,694,974 Example embodiments of system and method for magnetic resonance imaging (MRI) techniques for planning, real-time monitoring, control, and post-treatment assessment of high intensity focused ultrasound (HIFU) mechanical fractionation of biological material are disclosed. An adapted form of HIFU, referred to as "boiling histotripsy" (BH), can be used to cause mechanical fractionation of biological material. In contrast to conventional HIFU, which cause pure thermal ablation, BH can generate therapeutic destruction of biological tissue with a degree of control and precision that allows the process to be accurately measured and monitored in real-time as well as the outcome of the treatment can be evaluated using a variety of MRI techniques. Real-time monitoring also allow for real-time control of BH. |
|
30 Jun 2020
|
|
 |
 |
|
Pulse Amplifier for Driving Ultrasound Transducers Patent Number: 9,867,999 |
|
More Info
| |
|
16 Jan 2018
|
|
 |
|
|
Embodiments of the invention include improved radiofrequency (RF) pulse amplifier systems that incorporate an energy array comprising multiple capacitors connected in parallel. The energy array extends the maximum length of pulses and the maximum achievable peak power output of the amplifier when compared to similar systems. Embodiments also include systems comprising the amplifier configured to drive a load, wherein the load may include one or more ultrasound (e.g., piezoelectric) transducers Related methods of using the amplifier are also provided.
|
|
 |
|
Imaging Bubbles in a Medium Patent Number: 9,743,909 |
|
More Info
| |
|
29 Aug 2017
|
|
 |
|
|
A method for imaging a cavitation bubble includes producing a vibratory wave that induces a cavitation bubble in a medium, producing one or more detection waves directed toward the induced cavitation bubble, receiving one or more reflection waves, identifying a change in one or more characteristics of the induced cavitation bubble, and generating an image of the induced cavitation bubble using a computing device on the basis of the identified change in the one or more characteristics. The one or more received reflection waves correspond to at least one of the one or more produced detection waves reflection from the induced cavitation bubble. The identified change in one or more characteristics corresponds to the one or more received reflection waves.
|
|
 |
|
Methods and Systems for Non-invasive Treatment of Tissue Using High Intensity Focused Ultrasound Therapy Patent Number: 9,700,742 |
|
More Info
| |
|
11 Jul 2017
|
|
 |
|
|
Methods and systems for non-invasive treatment of tissue using high intensity focused ultrasound ("HIFU") therapy. A method of non-invasively treating tissue in accordance with an embodiment of the present technology, for example, can include positioning a focal plane of an ultrasound source at a target site in tissue. The ultrasound source can be configured to emit HIFU waves. The method can further include pulsing ultrasound energy from the ultrasound source toward the target site, and generating shock waves in the tissue to induce boiling of the tissue at the target site within milliseconds. The boiling of the tissue at least substantially emulsifies the tissue.
|
|
 |
|
Methods of Soft Tissue Emulsification using a Mechanism of Ultrasonic Atomization Inside Gas or Vapor Cavities and Associated Systems and Devices Patent Number: 9,498,651 |
|
More Info
| |
|
22 Nov 2016
|
|
 |
|
|
The present technology is directed to methods of soft tissue emulsification using a mechanism of ultrasonic atomization inside gas or vapor cavities, and associated systems and devices. In several embodiments, for example, a method of non-invasively treating tissue includes pulsing ultrasound energy from the ultrasound source toward the target site in tissue. The ultrasound source is configured to emit high intensity focused ultrasound (HIFU) waves. The target site comprises a pressure-release interface of a gas or vapor cavity located within the tissue. The method continues by generating shock waves in the tissue to induce a lesion in the tissue at the target site. The method additionally includes characterizing the lesion based on a degree of at least one of a mechanical or thermal ablation of the tissue.
|
|
 |
|
Methods and systems for non-invasive treatment of tissue using high intensity focused ultrasound therapy Patent Number: 8,876,740 |
|
More Info
| |
|
4 Nov 2014
|
|
 |
|
|
Methods and systems for non-invasive treatment of tissue using high intensity focused ultrasound (HIFU) therapy. A method of non-invasively treating tissue in accordance with an embodiment of the present technology, for example, can include positioning a focal plane of an ultrasound source at a target site in tissue. The ultrasound source can be configured to emit HIFU waves. The method can further include pulsing ultrasound energy from the ultrasound source toward the target site, and generating shock waves in the tissue to induce boiling of the tissue at the target site within milliseconds. The boiling of the tissue at least substantially emulsifies the tissue.
|
|
|
|
Publications
|
 |
|
A fully populated transrectal array for boiling histotripsy ablation of the prostate Rosnitskiy, P.B., G.P.L. Thomas, G.L. Lee, V.A. Khokhlova, O.A. Sapozhnikov, G.R. Schade, K.P. Morrison, F. Chaves, and T.D. Khokhlova, "A fully populated transrectal array for boiling histotripsy ablation of the prostate," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 72, 1336-1351, doi:10.1109/TUFFC.2025.3596780, 2025. |
|
More Info
| |
|
1 Oct 2025
|
|
 |
|
|
The endorectal ultrasound (US)-guided thermal ablation of prostate cancer (PCa) using high-intensity focused ultrasound (HIFU) is a widely used focal intervention. While generally safe and effective, it is not without challenges associated with heat diffusion and prefocal heating, which has spurred interest toward nonthermal and mechanical HIFU ablation regimes. Another challenge is the necessity to mechanically translate the HIFU transducer-commonly single-element or annular array-for volumetric treatments, which results in target shifts and transducer position readjustment. The 2-D arrays would address this problem, but their design is challenging in a small form factor. The element pattern must be tightly packed and aperiodic to maximize the active surface area and to suppress grating lobes, respectively. Here, we report on the design, fabrication, and performance evaluation of a 1.5-MHz 128-element transrectal HIFU array driven by Verasonics system capable of mechanical tissue ablation via boiling histotripsy (BH) under real-time coaxial US imaging guidance. A recently developed method for designing randomized, fully populated mosaic arrays was used to create the element pattern. The measured focus steering ranges of the fabricated array were 26 mm axially and 12 mm laterally in the BH regime, with driving voltage compensation by less than 43% and no grating lobe formation. Stress tests with a five-element prototype confirmed safe operating voltage of 850-V peak-to-peak, corresponding to the acoustic intensity of 542 W/cm(2) at the array surface. The array integrated with a 128-element US imaging probe driven by the same Verasonics system was successfully used to produce volumetric BH lesions in polyacrylamide (PAA) tissue-mimicking phantoms.
|
|
 |
|
Advancing boiling histotripsy dose in ex vivo and in vivo renal tissues via quantitative histological analysis and shear wave elastography Ponomarchuk, E., G. Thomas, M. Song, Y.-N. Wang, S. Totten, G. Schade, J. Thiel, M. Bruce, V. Khokhlova, and T. Khokhlova, "Advancing boiling histotripsy dose in ex vivo and in vivo renal tissues via quantitative histological analysis and shear wave elastography," Ultrasound Med. Biol., 50, 1936-1944, doi:10.1016/j.ultrasmedbio.2024.08.022, 2024. |
|
More Info
| |
|
1 Dec 2024
|
|
 |
|
|
Objective In the context of developing boiling histotripsy (BH) as a potential clinical approach for non-invasive mechanical ablation of kidney tumors, the concept of BH dose (BHD) was quantitatively investigated in porcine and canine kidney models in vivo and ex vivo.
Methods Volumetric lesions were produced in renal tissue using a 1.5-MHz 256-element HIFU-array with various pulsing protocols: pulse duration tp = 110 ms, number of pulses per point ppp = 115. Two BHD metrics were evaluated: BHD1 = ppp, BHD2 = tp × ppp. Quantitative assessment of lesion completeness was performed by their histological analysis and assignment of damage score to different renal compartments (i.e., cortex, medulla, and sinus). Shear wave elastography (SWE) was used to measure the Young's modulus of renal compartments in vivo vs ex vivo, and before vs after BH treatments.
Results In vivo tissue required lower BH doses to achieve identical degree of fractionation as compared to ex vivo. Renal cortex (homogeneous, low in collagen) was equal or higher in stiffness than medulla (anisotropic, collagenous), 5.812.2 kPa vs 4.79.6 kPa, but required lower BH doses to be fully fractionated. Renal sinus (fatty, irregular, with abundant collagenous structures) was significantly softer ex vivo vs in vivo, 4.95.1 kPa vs 9.715.2 kPa, but was barely damaged in either case with any tested BH protocols. BHD1 was shown to be relevant for planning the treatment of renal cortex (sufficient BHD1 = 5 pulses in vivo and 10 pulses ex vivo), while none of the tested doses resulted in complete fractionation of medulla or sinus. Post-treatment SWE imaging revealed reduction of tissue stiffness ex vivo by 2758%, increasing with the applied dose, and complete absence of shear waves within in vivo lesions, both indicative of tissue liquefaction.
Conclusion The results imply that tissue resistance to mechanical fractionation, and hence required BH dose, are not solely determined by tissue stiffness but also depend on its composition and structural arrangement, as well as presence of perfusion. The SWE-derived reduction of tissue stiffness with increasing BH doses correlated with tissue damage score, indicating potential of SWE for post-treatment confirmation of BH lesion completeness.
|
|
 |
|
Histotripsy: A method for mechanical tissue ablation with ultrasound Xu, Z., T.D. Khokhlova, C.S. Cho, and V.A. Khokhlova, "Histotripsy: A method for mechanical tissue ablation with ultrasound," Ann. Rev. Biomed. Eng., 26, 141-167, doi:10.1146/annurev-bioeng-073123-022334, 2024. |
|
More Info
| |
|
1 Jul 2024
|
|
 |
|
|
Histotripsy is a relatively new therapeutic ultrasound technology to mechanically liquefy tissue into subcellular debris using high-amplitude focused ultrasound pulses. In contrast to conventional high-intensity focused ultrasound thermal therapy, histotripsy has specific clinical advantages: the capacity for real-time monitoring using ultrasound imaging, diminished heat sink effects resulting in lesions with sharp margins, effective removal of the treated tissue, a tissue-selective feature to preserve crucial structures, and immunostimulation. The technology is being evaluated in small and large animal models for treating cancer, thrombosis, hematomas, abscesses, and biofilms; enhancing tumor-specific immune response; and neurological applications. Histotripsy has been recently approved by the US Food and Drug Administration to treat liver tumors, with clinical trials undertaken for benign prostatic hyperplasia and renal tumors. This review outlines the physical principles of various types of histotripsy; presents major parameters of the technology and corresponding hardware and software, imaging methods, and bioeffects; and discusses the most promising preclinical and clinical applications.
|
|
 |
|
Elastic properties of aging human hematoma model in vitro and its susceptibility to histotripsy liquefaction Ponomarchuk, E.M., and 12 others including T.D. Khokhlova, O.A. Sapozhnikov, and V.A. Khokhlova, "Elastic properties of aging human hematoma model in vitro and its susceptibility to histotripsy liquefaction," Ultrasound Med. Biol., 50, 927-938, doi:10.1016/j.ultrasmedbio.2024.02.019, 2024. |
|
More Info
| |
|
1 Jun 2024
|
|
 |
|
|
Tissue susceptibility to histotripsy disintegration has been reported to depend on its elastic properties. This work was aimed at investigation of histotripsy efficiency for liquefaction of human hematomas, depending on their stiffness and degree of retraction over time (010 d).
It was found that clotting time decreased from 113 to 25 min with the increase in blood temperature from 10°C to 37°C. The shear modulus increased to 0.53 ± 0.17 kPa during clotting and remained constant within 8 d of incubation at 2°C. Sample volumes decreased by 57% because of retraction within 10 d. SEM revealed significant echinocytosis but unchanged ultrastructure of the fibrin meshwork. Liquefaction rate and lesion dimensions produced with the same histotripsy protocols correlated with the increase in the degree of retraction and were lower in retracted samples versus freshly clotted samples. More than 80% of residual fibrin fragments after histotripsy treatment were shorter than 150 μm; the maximum length was 208 μm, allowing for unobstructed aspiration of the lysate with most clinically used needles.
The results indicate that hematoma susceptibility to histotripsy liquefaction is not entirely determined by its stiffness, and correlates with the retraction degree.
|
|
 |
|
Dynamic mode decomposition for transient cavitation bubbles imaging in pulsed high-intensity focused ultrasound therapy Song, M.H., O.A Sapozhnikov, V.A. Khokhlova, and T.D. Khokhlova, "Dynamic mode decomposition for transient cavitation bubbles imaging in pulsed high-intensity focused ultrasound therapy," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 71, 596-606, doi:10.1109/TUFFC.2024.3387351, 2024. |
|
More Info
| |
|
1 May 2024
|
|
 |
|
|
Pulsed high-intensity focused ultrasound (pHIFU) can induce sparse de novo inertial cavitation without the introduction of exogenous contrast agents, promoting mild mechanical disruption in targeted tissue. Because the bubbles are small and rapidly dissolve after each HIFU pulse, mapping transient bubbles and obtaining real-time quantitative metrics correlated with tissue damage are challenging. Prior work introduced Bubble Doppler, an ultrafast power Doppler imaging method as a sensitive means to map cavitation bubbles. The main limitation of that method was its reliance on conventional wall filters used in Doppler imaging and its optimization for imaging blood flow rather than transient scatterers. This study explores Bubble Doppler enhancement using dynamic mode decomposition (DMD) of a matrix created from a Doppler ensemble for mapping and extracting the characteristics of transient cavitation bubbles. DMD was first tested in silico with a numerical dataset mimicking the spatiotemporal characteristics of backscattered signal from tissue and bubbles. The performance of DMD filter was compared to other widely used Doppler wall filter-singular value decomposition (SVD) and infinite impulse response (IIR) high-pass filter. DMD was then applied to an ex vivo tissue dataset where each HIFU pulse was immediately followed by a plane wave Doppler ensemble. In silico DMD outperformed SVD and IIR high-pass filter and ex vivo provided physically interpretable images of the modes associated with bubbles and their corresponding temporal decay rates. These DMD modes can be trackable over the duration of pHIFU treatment using k-means clustering method, resulting in quantitative indicators of treatment progression.
|
|
 |
|
Treatment planning and aberration correction algorithm for HIFU ablation of renal tumors Rosnitskiy, P.B., T.D. Khokhlova, G.R. Schade, O.A. Sapozhnikov, and V.A. Khokhlova, "Treatment planning and aberration correction algorithm for HIFU ablation of renal tumors," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 71, 341-353, doi:10.1109/TUFFC.2024.3355390, 2024. |
|
More Info
| |
|
1 Mar 2024
|
|
 |
|
|
High-intensity focused ultrasound (HIFU) applications for thermal or mechanical ablation of renal tumors often encounter challenges due to significant beam aberration and refraction caused by oblique beam incidence, inhomogeneous tissue layers, and presence of gas and bones within the beam. These losses can be significantly mitigated through sonication geometry planning, patient positioning, and aberration correction using multielement phased arrays. Here, a sonication planning algorithm is introduced, which uses the simulations to select the optimal transducer position and evaluate the effect of aberrations and acoustic field quality at the target region after aberration correction. Optimization of transducer positioning is implemented using a graphical user interface (GUI) to visualize a segmented 3-D computed tomography (CT)-based acoustic model of the body and to select sonication geometry through a combination of manual and automated approaches. An HIFU array (1.5 MHz, 256 elements) and three renal cell carcinoma (RCC) cases with different tumor locations and patient body habitus were considered. After array positioning, the correction of aberrations was performed using a combination of backpropagation from the focus with an ordinary least squares (OLS) optimization of phases at the array elements. The forward propagation was simulated using a combination of the Rayleigh integral and k-space pseudospectral method (k-Wave toolbox). After correction, simulated HIFU fields showed tight focusing and up to threefold higher maximum pressure within the target region. The addition of OLS optimization to the aberration correction method yielded up to 30% higher maximum pressure compared to the conventional backpropagation and up to 250% higher maximum pressure compared to the ray-tracing method, particularly in strongly distorted cases.
|
|
 |
|
Enhancement of boiling histotripsy by steering the focus axially during the pulse delivery Thomas, G.P.L., T.D. Khokhlova, O.A. Sapozhnikov, and V.A. Khokhlova, "Enhancement of boiling histotripsy by steering the focus axially during the pulse delivery," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 70, 865-875, doi:10.1109/TUFFC.2023.3286759, 2023. |
|
More Info
| |
|
1 Aug 2023
|
|
 |
|
|
Boiling histotripsy (BH) is a pulsed high-intensity focused ultrasound (HIFU) method relying on the generation of high-amplitude shocks at the focus, localized enhanced shock-wave heating, and bubble activity driven by shocks to induce tissue liquefaction. BH uses sequences of 120 ms long pulses with shock fronts of over 60 MPa amplitude, initiates boiling at the focus of the HIFU transducer within each pulse, and the remainder shocks of the pulse then interact with the boiling vapor cavities. One effect of this interaction is the creation of a prefocal bubble cloud due to reflection of shocks from the initially generated mm-sized cavities: the shocks are inverted when reflected from a pressure-release cavity wall resulting in sufficient negative pressure to reach intrinsic cavitation threshold in front of the cavity. Secondary clouds then form due to shock-wave scattering from the first one. Formation of such prefocal bubble clouds has been known as one of the mechanisms of tissue liquefaction in BH. Here, a methodology is proposed to enlarge the axial dimension of this bubble cloud by steering the HIFU focus toward the transducer after the initiation of boiling until the end of each BH pulse and thus to accelerate treatment. A BH system comprising a 1.5 MHz 256-element phased array connected to a Verasonics V1 system was used. High-speed photography of BH sonications in transparent gels was performed to observe the extension of the bubble cloud resulting from shock reflections and scattering. Volumetric BH lesions were then generated in ex vivo tissue using the proposed approach. Results showed up to almost threefold increase of the tissue ablation rate with axial focus steering during the BH pulse delivery compared to standard BH.
|
|
 |
|
Pilot ex vivo study on non-thermal ablation of human prostate adenocarcinoma tissue using boiling histotripsy Rosnitskiy, P.B., and 16 others including O.A. Sapozhnikov, A.D. Maxwell, Y.-N. Wang, and V.A. Khokhlova, "Pilot ex vivo study on non-thermal ablation of human prostate adenocarcinoma tissue using boiling histotripsy," Ultrasonics, 133, doi:10.1016/j.ultras.2023.107029, 2023. |
|
More Info
| |
|
1 Aug 2023
|
|
 |
|
|
Focused ultrasound technologies are of growing interest for noninvasive ablation of localized prostate cancer (PCa). Here we present the results of the first case study evaluating the feasibility of non-thermal mechanical ablation of human prostate adenocarcinoma tissue using the boiling histotripsy (BH) method on ex vivo tissue. High intensity focused ultrasound field was generated using a 1.5-MHz custom-made transducer with nominal F#=0.75. A sonication protocol of 734 W acoustic power, 10-ms long BH-pulses, 30 pulses per focal spot, 1 % duty cycle, and 1 mm distance between single foci was tested in an ex vivo human prostate tissue sample containing PCa. The protocol used here has been successfully applied in the previous BH studies for mechanical disintegration of ex vivo prostatic human tissue with benign hyperplasia. BH treatment was monitored using B-mode ultrasound. Post-treatment histologic analysis demonstrated BH produced liquefaction of the targeted tissue volume. BH treated benign prostate parenchyma and PCa had similar tissue fractionation into subcellular fragments. The results of the study demonstrated that PCa tumor tissue can be mechanically ablated using the BH method. Further studies will aim on optimizing protocol parameters to accelerate treatment while maintaining complete destruction of the targeted tissue volume into subcellular debris.
|
|
 |
|
The histotripsy spectrum: Differences and similarities in techniques and instrumentation Williams, R.P., J.C. Simon, V.A. Khokhlova, O.A. Sapozhnikov, and T.D. Khokhlova, "The histotripsy spectrum: Differences and similarities in techniques and instrumentation," Int. J. Hyperthermia, 40, doi:10.1080/02656736.2023.2233720, 2023. |
|
More Info
| |
|
17 Jul 2023
|
|
 |
|
|
Since its inception about two decades ago, histotripsy a non-thermal mechanical tissue ablation technique has evolved into a spectrum of methods, each with distinct potentiating physical mechanisms: intrinsic threshold histotripsy, shock-scattering histotripsy, hybrid histotripsy, and boiling histotripsy. All methods utilize short, high-amplitude pulses of focused ultrasound delivered at a low duty cycle, and all involve excitation of violent bubble activity and acoustic streaming at the focus to fractionate tissue down to the subcellular level. The main differences are in pulse duration, which spans microseconds to milliseconds, and ultrasound waveform shape and corresponding peak acoustic pressures required to achieve the desired type of bubble activity. In addition, most types of histotripsy rely on the presence of high-amplitude shocks that develop in the pressure profile at the focus due to nonlinear propagation effects. Those requirements, in turn, dictate aspects of the instrument design, both in terms of driving electronics, transducer dimensions and intensity limitations at surface, shape (primarily, the F-number) and frequency. The combination of the optimized instrumentation and the bio-effects from bubble activity and streaming on different tissues, lead to target clinical applications for each histotripsy method. Here, the differences and similarities in the physical mechanisms and resulting bioeffects of each method are reviewed and tied to optimal instrumentation and clinical applications.
|
|
 |
|
Initial assessment of boiling histotripsy for mechanical ablation of ex vivo human prostate tissue Khokhlova, V.A., and 15 others including, O.A. Sapozhnikov, A.D. Maxwell, and Y.-N. Wang, "Initial assessment of boiling histotripsy for mechanical ablation of ex vivo human prostate tissue," Ultrasound Med. Biol., 49, 62-71, doi:10.1016/j.ultrasmedbio.2022.07.014, 2023. |
|
More Info
| |
|
1 Jan 2023
|
|
 |
|
|
Boiling histotripsy (BH) is a focused ultrasound technology that uses millisecond-long pulses with shock fronts to induce mechanical tissue ablation. The pulsing scheme and mechanisms of BH differ from those of cavitation cloud histotripsy, which was previously developed for benign prostatic hyperplasia. The goal of the work described here was to evaluate the feasibility of using BH to ablate fresh ex vivo human prostate tissue as a proof of principle for developing BH for prostate applications. Fresh human prostate samples (N = 24) were obtained via rapid autopsy (<24 h after death, institutional review board exempt). Samples were analyzed using shear wave elastography to ensure that mechanical properties of autopsy tissue were clinically representative. Samples were exposed to BH using 10- or 1-ms pulses with 1% duty cycle under real-time B-mode and Doppler imaging. Volumetric lesions were created by sonicating 14 rectangular planes spaced 1 mm apart, containing a grid of foci spaced 12 mm apart. Tissue then was evaluated grossly and histologically, and the lesion content was analyzed using transmission electron microscopy and scanning electron microscopy. Observed shear wave elastography characterization of ex vivo prostate tissue (37.9 ± 22.2 kPa) was within the typical range observed clinically. During BH, hyperechoic regions were visualized at the focus on B-mode, and BH-induced bubbles were also detected using power Doppler. As treatment progressed, hypoechoic regions of tissue appeared, suggesting successful tissue fractionation. BH treatment was twofold faster using shorter pulses (1 ms vs. 10 ms). Histological analysis revealed lesions containing completely homogenized cell debris, consistent with histotripsy-induced mechanical ablation. It was therefore determined that BH is feasible in fresh ex vivo human prostate tissue producing desired mechanical ablation. The study supports further work aimed at translating BH technology as a clinical option for prostate ablation.
|
|
 |
|
Quantitative assessment of boiling histotripsy progression based on color Doppler measurements Song, M.H., G.P.L. Thomas, V.A. Khokhlova, O.A. Sapozhnikov, M.R. Bailey, A.D. Maxwell, P.V. Yuldashev, and T.D. Khokhlova, "Quantitative assessment of boiling histotripsy progression based on color Doppler measurements," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 69, 3255-3269, doi:10.1109/TUFFC.2022.3212266, 2022. |
|
More Info
| |
|
1 Dec 2022
|
|
 |
|
|
Boiling histotripsy (BH) is a mechanical tissue liquefaction method that uses sequences of millisecond-long high intensity focused ultrasound (HIFU) pulses with shock fronts. The BH treatment generates bubbles that move within the sonicated volume due to acoustic radiation force. Since the velocity of the bubbles and tissue debris is expected to depend on the lesion size and liquefaction completeness, it could provide a quantitative metric of the treatment progression. In this study, the motion of bubble remnants and tissue debris immediately following BH pulses was investigated using high-pulse repetition frequency (PRF) plane-wave color Doppler ultrasound in ex vivo myocardium tissue. A 256-element 1.5 MHz spiral HIFU array with a coaxially integrated ultrasound imaging probe (ATL P4-2) produced 10 ms BH pulses to form volumetric lesions with electronic beam steering. Prior to performing volumetric BH treatments, the motion of intact myocardium tissue and anticoagulated bovine blood following isolated BH pulses was assessed as two limiting cases. In the liquid blood the velocity of BH-induced streaming at the focus reached over 200 cm/s, whereas the intact tissue was observed to move toward the HIFU array consistent with elastic rebound of tissue. Over the course of volumetric BH treatments tissue motion at the focus locations was dependent on the axial size of the forming lesion relative to the corresponding size of the HIFU focal area. For axially small lesions, the maximum velocity after the BH pulse was directed toward the HIFU transducer and monotonically increased over time from about 20100 cm/s as liquefaction progressed, then saturated when tissue was fully liquefied. For larger lesions obtained by merging multiple smaller lesions in the axial direction, the high-speed streaming away from the HIFU transducer was observed at the point of full liquefaction. Based on these observations, the maximum directional velocity and its location along the HIFU propagation axis were proposed and evaluated as candidate metrics of BH treatment completeness.
|
|
 |
|
Impact of treatment trajectory on temperature field uniformity in biological tissue irradiated by ultrasound pulses with shocks Pestova, P.A., M.M. Karzova, P.V. Yuldashev, W. Kreider, and V.A. Khokhlova, "Impact of treatment trajectory on temperature field uniformity in biological tissue irradiated by ultrasound pulses with shocks," Acoust. Phys., 67, 250-258, doi:10.1134/S106377102103012X, 2021. |
|
More Info
| |
|
9 Nov 2021
|
|
 |
|
|
High intensity focused ultrasound (HIFU) treatments typically involve the ablation of tissue volumes comprising multiple focal sites. One aspect of treatment planning involves the definition of a sequence of ultrasound pulses and corresponding focal sites as the sonication trajectory. Here, numerical simulations of the thermal effects of different trajectories are performed for HIFU exposures delivered to an ex vivo bovine liver sample by a clinical array (Sonalleve V2 3.0T system, Profound Medical Corp., Canada). Simulations consider boiling histotripsy regime with millisecond-long pulses that include shocks. Focusing of the ultrasound beam in tissue was modeled by the Westervelt equation, and the temperature field was modeled by the bioheat equation. To explore different treatment strategies, trajectories were considered with discrete foci located along two or four concentric circles with radii from 2 to 8 mm. Two approaches for traversing these focal sites were compared: In the first approach each discrete focus was sonicated by a sequence of 15 pulses before moving to the next site in the trajectory. In the second approach, each focus was sonicated once before moving to the next site, with sonications over the whole trajectory repeated 15 times. The influence of the trajectory’s size and the pulsing strategy on the temperature field was analyzed. It is shown that the structure of the temperature field is more uniform with a longer time interval between repeated irradiation of each focus, and the optimal time interval ranges from three to six pulse repetition periods.
|
|
 |
|
Introduction to the special issue on histotripsy: Approaches, mechanisms, hardware, and applications Zhen, X., V.A. Khokhlova, K.A. Wear, J.-F. Aubry, and T.A. Bigelow, "Introduction to the special issue on histotripsy: Approaches, mechanisms, hardware, and applications," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 68, 2834-2836, doi:10.1109/TUFFC.2021.3102092, 2021. |
|
More Info
| |
|
1 Sep 2021
|
|
 |
|
|
Histotripsy is a therapeutic ultrasound technology to liquefy tissue into acellular debris using sequences of high-power focused ultrasound pulses. Research on histotripsy has been rapidly growing in the past decade; newer applications are being proposed and evaluated for clinical use. In contrast to conventional high-intensity focused ultrasound (HIFU) thermal therapy, the major mechanism of histotripsy is mechanical, which enables localized tissue disintegration at the target sites without thermal damage to overlying and surrounding tissues. Two major approaches, cavitational histotripsy and boiling histotripsy, with two different mechanisms, have been extensively explored lately. Histotripsy therapy is being evaluated for treating cancer, thrombosis, hematomas, abscess, neurological diseases, for inducing an enhanced immune response and performing noninvasive biopsy in preclinical studies with small and large animal models. The first clinical trials using histotripsy for benign prostatic hyperplasia, liver cancer, and calcified aortic stenosis have been undertaken.
|
|
 |
|
Partial respiratory motion compensation for abdominal extracorporeal boiling histotripsy treatments with a robotic arm Thomas, G.P.L., T.D. Khokhlova, and V.A. Khokhlova, "Partial respiratory motion compensation for abdominal extracorporeal boiling histotripsy treatments with a robotic arm," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 68, 2861-2870, doi:10.1109/TUFFC.2021.3075938, 2021. |
|
More Info
| |
|
1 Sep 2021
|
|
 |
|
|
Extracorporeal boiling histotripsy (BH), a noninvasive method for mechanical tissue disintegration, is getting closer to clinical applications. However, the motion of the targeted organs, mostly resulting from the respiratory motion, reduces the efficiency of the treatment. Here, a practical and affordable unidirectional respiratory motion compensation method for BH is proposed and evaluated in ex vivo tissues. The BH transducer is fixed on a robotic arm following the motion of the skin, which is tracked using an inline ultrasound imaging probe. In order to compensate for system lags and obtain a more accurate compensation, an autoregressive motion prediction model is implemented. BH pulse gating is also implemented to ensure targeting accuracy. The system is then evaluated with ex vivo BH treatments of tissue samples undergoing motion simulating breathing with the movement of amplitudes between 5 and 10 mm, the frequency between 16 and 18 breaths/min, and a maximum speed of 14.2 mm/s. Results show a reduction of at least 89% of the value of the targeting error during treatment while only increasing the treatment time by no more than 1%. The lesions obtained by treating with the motion compensation were close in size and affected area to the no-motion case, whereas lesions obtained without the compensation were often incomplete and had larger affected areas. This approach to motion compensation could benefit extracorporeal BH and other histotripsy methods in clinical translation.
|
|
 |
|
Ultrastructural analysis of volumetric histotripsy bio-effects in large human hematomas Ponomarchuk, E.M., and 12 others including Y.-N. Wang, O.A. Sapozhnikov, and V.A. Khokhlova, "Ultrastructural analysis of volumetric histotripsy bio-effects in large human hematomas," Ultrasound Biol. Med., 47, 2608-2621, doi:10.1016/j.ultrasmedbio.2021.05.002, 2021. |
|
More Info
| |
|
1 Sep 2021
|
|
 |
|
|
Large-volume soft tissue hematomas are a serious clinical problem, which, if untreated, can have severe consequences. Current treatments are associated with significant pain and discomfort. It has been reported that in an in vitro bovine hematoma model, pulsed high-intensity focused ultrasound (HIFU) ablation, termed histotripsy, can be used to rapidly and non-invasively liquefy the hematoma through localized bubble activity, enabling fine-needle aspiration. The goals of this study were to evaluate the efficiency and speed of volumetric histotripsy liquefaction using a large in vitro human hematoma model. Large human hematoma phantoms (85 cc) were formed by recalcifying blood anticoagulated with citrate phosphate dextrose/salineadenineglucosemannitol solution. Typical boiling histotripsy pulses (10 or 2 ms) or hybrid histotripsy pulses using higher-amplitude and shorter pulses (0.4 ms) were delivered at 1% duty cycle while continuously translating the HIFU focus location. Histotripsy exposures were performed under ultrasound guidance with a 1.5-MHz transducer (8-cm aperture, F# = 0.75). The volume of liquefied lesions was determined by ultrasound imaging and gross inspection. Untreated hematoma samples and samples of the liquefied lesions aspirated using a fine needle were analyzed cytologically and ultrastructurally with scanning electron microscopy. All exposures resulted in uniform liquid-filled voids with sharp edges; liquefaction speed was higher for exposures with shorter pulses and higher shock amplitudes at the focus (up to 0.32, 0.68 and 2.62 mL/min for 10-, 2- and 0.4-ms pulses, respectively). Cytological and ultrastructural observations revealed completely homogenized blood cells and fibrin fragments in the lysate. Most of the fibrin fragments were less than 20 μm in length, but a number of fragments were up to 150 μm. The lysate with residual debris of that size would potentially be amenable to fine-needle aspiration without risk for needle clogging in clinical implementation.
|
|
 |
|
A prototype therapy system for boiling histotripsy in abdominal targets based on a 256-element spiral array Bawiec, C.R., T.D. Khokhlova, O.A Sapozhnikov, P.B. Rosnitskiy, B.W. Cunitz, M.A. Ghanem, C. Hunter, W. Kreider, G.R. Schade, P.V. Yuldashev, and V.A. Khokhlova, "A prototype therapy system for boiling histotripsy in abdominal targets based on a 256-element spiral array," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 68, 1496-1510, doi:10.1109/TUFFC.2020.3036580, 2021. |
|
More Info
| |
|
1 May 2021
|
|
 |
|
|
Boiling histotripsy (BH) uses millisecond-long ultrasound (US) pulses with high-amplitude shocks to mechanically fractionate tissue with potential for real-time lesion monitoring by US imaging. For BH treatments of abdominal organs, a high-power multielement phased array system capable of electronic focus steering and aberration correction for body wall inhomogeneities is needed. In this work, a preclinical BH system was built comprising a custom 256-element 1.5-MHz phased array (Imasonic, Besançon, France) with a central opening for mounting an imaging probe. The array was electronically matched to a Verasonics research US system with a 1.2-kW external power source. Driving electronics and software of the system were modified to provide a pulse average acoustic power of 2.2 kW sustained for 10 ms with a 12-Hz repetition rate for delivering BH exposures. System performance was characterized by hydrophone measurements in water combined with nonlinear wave simulations based on the Westervelt equation. Fully developed shocks of 100-MPa amplitude are formed at the focus at 275-W acoustic power. Electronic steering capabilities of the array were evaluated for shock-producing conditions to determine power compensation strategies that equalize BH exposures at multiple focal locations across the planned treatment volume. The system was used to produce continuous volumetric BH lesions in ex vivo bovine liver with 1-mm focus spacing, 10-ms pulselength, five pulses/focus, and 1% duty cycle.
|
|
 |
|
Treating porcine abscesses with histotripsy: A pilot study Matula, T.J., Y.-N. Wang, T. Khokhlova, D.F. Leotta, J. Kucewicz, A.A. Brayman, M. Bruce, A.D. Maxwell, B.E. MacConaghy, G. Thomas, V.P. Chernikov, S.V. Buravkov, V.A. Khokhlova, K. Richmond, K. Chan, W. Monsky, "Treating porcine abscesses with histotripsy: A pilot study," Ultrasound Med. Biol., 47, 603-619, doi:10.1016/j.ultrasmedbio.2020.10.011, 2021. |
|
More Info
| |
|
1 Mar 2021
|
|
 |
|
|
Infected abscesses are walled-off collections of pus and bacteria. They are a common sequela of complications in the setting of surgery, trauma, systemic infections and other disease states. Current treatment is typically limited to antibiotics with long-term catheter drainage, or surgical washout when inaccessible to percutaneous drainage or unresponsive to initial care efforts. Antibiotic resistance is also a growing concern. Although bacteria can develop drug resistance, they remain susceptible to thermal and mechanical damage. In particular, short pulses of focused ultrasound (i.e., histotripsy) generate mechanical damage through localized cavitation, representing a potential new paradigm for treating abscesses non-invasively, without the need for long-term catheterization and antibiotics. In this pilot study, boiling and cavitation histotripsy treatments were applied to subcutaneous and intramuscular abscesses developed in a novel porcine model. Ultrasound imaging was used to evaluate abscess maturity for treatment monitoring and assessment of post-treatment outcomes. Disinfection was quantified by counting bacteria colonies from samples aspirated before and after treatment. Histopathological evaluation of the abscesses was performed to identify changes resulting from histotripsy treatment and potential collateral damage. Cavitation histotripsy was more successful in reducing the bacterial load while having a smaller treatment volume compared with boiling histotripsy. The results of this pilot study suggest focused ultrasound may lead to a technology for in situ treatment of acoustically accessible abscesses.
|
|
 |
|
Effect of stiffness of large extravascular hematomas on their susceptibility to boiling histotripsy liquefaction in vitro Khokhlova, T.D., J.C. Kucewicz, E.M. Ponomarchuk, C. Hunter, M. Bruce, V.A. Khokhlova, T.J. Matula, and W. Monsky, "Effect of stiffness of large extravascular hematomas on their susceptibility to boiling histotripsy liquefaction in vitro," Ultrasound Med. Biol., 46, 2007-2016, doi:10.1016/j.ultrasmedbio.2020.04.023, 2020. |
|
More Info
| |
|
1 Aug 2020
|
|
 |
|
|
Large intra-abdominal, retroperitoneal and intramuscular hematomas are common consequences of sharp and blunt trauma and post-surgical bleeds, and often threaten organ failure, compartment syndrome or spontaneous infection. Current therapy options include surgical evacuation and placement of indwelling drains that are not effective because of the viscosity of the organized hematoma. We have previously reported the feasibility of using boiling histotripsy (BH) a pulsed high-intensity focused ultrasound method for liquefaction of large volumes of freshly coagulated blood and subsequent fine-needle aspiration. The goal of this work was to evaluate the changes in stiffness of large coagulated blood volumes with aging and retraction in vitro, and to correlate these changes with the size of the BH void and, therefore, the susceptibility of the material to BH liquefaction. Large-volume (55200 mL) whole-blood clots were fabricated in plastic molds from human and bovine blood, either by natural clotting or by recalcification of anticoagulated blood, with or without addition of thrombin. Retraction of the clots was achieved by incubation for 3 h, 3 d or 8 d. The shear modulus of the samples was measured with a custom-built indentometer and shear wave elasticity (SWE) imaging. Sizes of single liquefied lesions produced with a 1.5-MHz high-intensity focused ultrasound transducer within a 30-s standard BH exposure served as the metric for susceptibility of clot material to this treatment. Neither the shear moduli of naturally clotted human samples (0.52 ± 0.08 kPa), nor their degree of retraction (ratio of expelled fluid to original volume 50%–58%) depended on the length of incubation within 08 d, and were significantly lower than those of bovine samples (2.85 ± 0.17 kPa, retraction 5%38%). In clots made from anticoagulated bovine blood, the variation of calcium chloride concentration within 5–40 mmol/L did not change the stiffness, whereas lower concentrations and the addition of thrombin resulted in significantly softer clots, similar to naturally clotted human samples. Within the achievable shear modulus range (0.41.6 kPa), the width of the BH-liquefied lesion was more affected by the changes in stiffness than the length of the lesion. In all cases, however, the lesions were larger compared with any soft tissue liquefied with the same BH parameters, indicating higher susceptibility of hematomas to BH damage. These results suggest that clotted bovine blood with added thrombin is an acceptable in vitro model of both acute and chronic human hematomas for assessing the efficiency of BH liquefaction strategies.
|
|
 |
|
Histotripsy: The next generation of high-intensity focused ultrasound for focal prostate cancer therapy Dubinsky, T.J., T.D. Khokhlova, V. Khokhlova, and G.R. Schade, "Histotripsy: The next generation of high-intensity focused ultrasound for focal prostate cancer therapy," J. Ultrasound Med., 39, 1057-1067, doi:10.1002/jum.15191, 2020. |
|
More Info
| |
|
1 Jun 2020
|
|
 |
|
|
This article reviews the most current methods and technological aspects of highâ€intensity focused ultrasound (HIFU), which is termed histotripsy. The rationale for focal therapy for prostate carcinoma rather than prostatectomy, which is being used extensively throughout Europe and Asia, is presented, and an argument for why HIFU is the modality of choice for primary therapy and recurrent disease is offered. The article presents a review of the technical advances including higher ultrasound beam energy than current thermal HIFU which allows for more accurate tissue targeting, less collateral tissue damage, and faster treatment times. Finally, the article presents a discussion about the advantage of ultrasound guidance for histotripsy in preference to magnetic resonance imaging guidance primarily based on cost, ease of application, and portability.
|
|
 |
|
Pilot in vivo studies on transcutaneous boiling histotripsy in porcine liver and kidney Khokhlova, T.D., G.R. Schade, Y.-N. Wang, S.V. Buravkov, V.P. Chernikov, J.C. Simon, F. Starr, A.D. Maxwell, M.R. Bailey, W. Kreider, and V.A. Khokhlova, "Pilot in vivo studies on transcutaneous boiling histotripsy in porcine liver and kidney," Sci. Rep., 9, 20176, doi:10.1038/s41598-019-56658-7, 2019. |
|
More Info
| |
|
27 Dec 2019
|
|
 |
|
|
Boiling histotripsy (BH) is a High Intensity Focused Ultrasound (HIFU) method for precise mechanical disintegration of target tissue using millisecond-long pulses containing shocks. BH treatments with real-time ultrasound (US) guidance allowed by BH-generated bubbles were previously demonstrated ex vivo and in vivo in exposed porcine liver and small animals. Here, the feasibility of US-guided transabdominal and partially transcostal BH ablation of kidney and liver in an acute in vivo swine model was evaluated for 6 animals. BH parameters were: 1.5 MHz frequency, 530 pulses of 110 ms duration per focus, 1% duty cycle, peak acoustic powers 0.93.8 kW, sonication foci spaced 11.5 mm apart in a rectangular grid with 515 mm linear dimensions. In kidneys, well-demarcated volumetric BH lesions were generated without respiratory gating and renal medulla and collecting system were more resistant to BH than cortex. The treatment was accelerated 10-fold by using shorter BH pulses of larger peak power without affecting the quality of tissue fractionation. In liver, respiratory motion and aberrations from subcutaneous fat affected the treatment but increasing the peak power provided successful lesion generation. These data indicate BH is a promising technology for transabdominal and transcostal mechanical ablation of tumors in kidney and liver.
|
|
 |
|
Mechanical decellularization of tissue volumes using boiling histotripsy Wang, Y.-N., T.D. Khokhlova, S. Buravkov, V. Chernikov, W. Greider, A. Partanen, N. Farr, A. Maxwell, G.R. Schade, and V.A. Khokhlova, "Mechanical decellularization of tissue volumes using boiling histotripsy," Phys. Med. Biol., 6, 235023, doi: |
|
More Info
| |
|
4 Dec 2018
|
|
 |
|
|
High intensity focused ultrasound (HIFU) is rapidly advancing as an alternative therapy for non-invasively treating specific cancers and other pathological tissues through thermal ablation. A new type of HIFU therapy boiling histotripsy (BH) aims at mechanical fractionation of into subcellular fragments, with a range of accompanying thermal effects that can be tuned from none to substantial depending on the requirements of the application. The degree of mechanical tissue damage induced by BH has been shown to depend on the tissue type, with collagenous structures being most resistant, and cellular structures being most sensitive. This has been reported for single BH lesions, but has not been replicated in large volumes. Such tissue selectivity effect has potential uses involving tissue decellularization for biofabrication technologies as well as mechanical ablation by BH while sparing critical structures. The goal of this study was to investigate tissue decellularization effect in larger, clinically relevant liquefied volumes of tissue, and to evaluate the accumulated thermal effect in the volumetric lesions under different exposure parameters. All BH exposures were performed with a 256-element 1.2-MHz array of a magnetic resonance imaging guided HIFU (MR-HIFU) clinical system (Sonalleve V1, Profound Medical Inc, Mississauga, Canada). The volumetric BH lesions were produced in degassed ex vivo bovine liver using 110-ms long pulses with in situ shock amplitudes of 75100 MPa at the focus and pulse repetition frequencies (PRFs) of 110 Hz covering a range of effects from pure mechanical homogenization to thermal ablation. Multimodal analysis of the lesions was then performed, including microstructure (histological), ultrastructure (electron microscopy), and molecular (biochemistry) methods. Results show a range of tissue effects in terms of the degree of tissue selectivity and the amount of heat generated in large BH lesions, thereby demonstrating potential for treatments tailored to different clinical applications.
|
|
 |
|
Inactivation of planktonic Escherichia coli by focused 1-MHz ultrasound pulses with shocks: Efficacy and kinetics upon volume scale-up Brayman, A.A., B.E. MacConaghy, Y.-N. Wang, K.T. Chan, W.L. Monsky, V.P. Chernikov, S.V. Buravkov, V.A. Khokhlova, and T.J. Matula, "Inactivation of planktonic Escherichia coli by focused 1-MHz ultrasound pulses with shocks: Efficacy and kinetics upon volume scale-up," Ultrasound Med. Biol., 44, 1996-2008, doi:10.1016/j.ultrasmedbio.2018.05.010, 2018. |
|
More Info
| |
|
1 Sep 2018
|
|
 |
|
|
This study addresses inactivation of E. coli in either 5- or 10-mL volumes, which were 50- to 100-fold greater than used in an earlier study (Brayman et al. 2017). Cells were treated with 1-MHz pulsed high-intensity focused ultrasound (10 cycles, 2-kHz repetition frequency, +65/12.8 MPa focal pressures). The surviving fraction was assessed by coliform assay, and inactivation demonstrated curvilinear kinetics. The reduction of surviving fraction to 50% required 2.5 or 6 min in 5- or 10-mL samples, respectively. Exposure of 5 mL for 20 min reduced the surviving fraction to ~1%; a similar exposure of 10-mL samples reduced the surviving fraction to ~10%. Surviving cells from 5-min exposures appeared normal under light microscopy, with minimal debris; after 20 min, debris dominated. Transmission electron microscopy images of insonated samples showed some undamaged cells, a few damaged but largely intact cells and comminuted debris. Cellular damage associated with substantive but incomplete levels of inactivation can be variable, ranging from membrane holes tens of nanometers in diameter to nearly complete comminution.
|
|
 |
|
A prototype therapy system for transcutaneous application of boiling histotripsy Maxwell, A.D., P.V. Yuldashev, W. Kreider, T.D. Khokhlova, G.R. Schade, T.L. Hall, O.A. Sapozhnikov, M.R. Bailey, and V.A. Khokhlova, "A prototype therapy system for transcutaneous application of boiling histotripsy," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 64, 1542-1557, doi:10.1109/TUFFC.2017.2739649, 2017. |
|
More Info
| |
|
1 Oct 2017
|
|
 |
|
|
Boiling histotripsy (BH) is a method of focused ultrasound surgery that noninvasively applies millisecond-length pulses with high-amplitude shock fronts to generate liquefied lesions in tissue. Such a technique requires unique outputs compared to a focused ultrasound thermal therapy apparatus, particularly to achieve high in situ pressure levels through intervening tissue. This paper describes the design and characterization of a system capable of producing the necessary pressure to transcutaneously administer BH therapy through clinically relevant overlying tissue paths using pulses with duration up to 10 ms. A high-voltage electronic pulser was constructed to drive a 1-MHz focused ultrasound transducer to produce shock waves with amplitude capable of generating boiling within the pulse duration in tissue. The system output was characterized by numerical modeling with the 3-D Westervelt equation using boundary conditions established by acoustic holography measurements of the source field. Such simulations were found to be in agreement with directly measured focal waveforms. An existing derating method for nonlinear therapeutic fields was used to estimate in situ pressure levels at different tissue depths. The system was tested in ex vivo bovine liver samples to create BH lesions at depths up to 7 cm. Lesions were also created through excised porcine body wall (skin, adipose, and muscle) with 35 cm thickness. These results indicate that the system is capable of producing the necessary output for transcutaneous ablation with BH.
|
|
 |
|
Dependence of boiling histotripsy treatment efficiency on HIFU frequency and focal pressure levels Khokhlova, T.D., Y.A. Haider, A.D. Maxwell, W. Kreider, M.R. Bailey, and V.A. Khokhlova, "Dependence of boiling histotripsy treatment efficiency on HIFU frequency and focal pressure levels," Ultrasound Med. Biol., 9, 1975-1985, doi:10.1016/j.ultrasmedbio.2017.04.030, 2017. |
|
More Info
| |
|
1 Sep 2017
|
|
 |
|
|
Boiling histotripsy (BH) is a high-intensity focused ultrasound (HIFU)–based method of mechanical tissue fractionation that utilizes millisecond-long bursts of HIFU shock waves to cause boiling at the focus in milliseconds. The subsequent interaction of the incoming shocks with the vapor bubble mechanically lyses surrounding tissue and cells. The acoustic parameter space for BH has been investigated previously and an inverse dependence between the HIFU frequency and the dimensions of a BH lesion has been observed. The primary goal of the present study was to investigate in more detail the ablation rate and reliability of BH in the frequency range relevant to treatment of deep abdominal tissue targets (12 MHz). The second goal was to investigate the effect of focal peak pressure levels and shock amplitude on BH lesion formation, given a constant duty factor, a constant ratio of the pulse duration to the time to reach boiling and a constant number of BH pulses. A custom-built 12-element sector array HIFU transducer with F-number = 1.05 was used in all experiments. BH pulses at 5 different frequencies (1, 1.2, 1.5, 1.7 and 1.9 MHz) were delivered to optically transparent polyacrylamide gel phantoms and ex vivo bovine liver and myocardium tissue to observe cavitation and boiling bubble activity with high-speed photography and B-mode ultrasound imaging, correspondingly. In gel phantoms, a cavitation bubble cloud was shown to form prefocally and to shield the focus in all exposures at 1 and 1.2 MHz and in the highest amplitude exposures at 1.51.7 MHz; shielding was not observed at 1.9 MHz. In ex vivo tissue, this shielding effect was observed in 25% of exposures when peak negative in situ pressure exceeded 10.2 MPa at 1 MHz and 14.5 MPa at 1.5 MHz. When shielding occurred, the exposures resulted in mild tissue disruption in the prefocal region, but not liquefaction. The dimensions of liquefied lesions followed the inverse proportionality trend with frequency; consequently, the frequency range of 1.21.5 MHz appeared to be preferable for BH exposures in terms of the compromise between the ablation rate and reliability. The lesion size was independent of the duration of the BH pulses (or the total "HIFU on" time), provided that the number of pulses was constant and boiling was induced within each pulse. Thus, the use of shorter (1 ms vs. 10 ms), higher amplitude BH pulses allowed up to 10-fold reduction in treatment time for a given duty factor.
|
|
 |
|
Design of HIFU transducers for generating specified nonlinear ultrasound fields Rosnitskiy, P.B., P.V. Yuldashev, O.A. Sapozhnikov, A.D. Maxwell, W. Greider, M.R. Bailey, and V.A. Khokhlova, "Design of HIFU transducers for generating specified nonlinear ultrasound fields," IEEE Trans. Ultrason., Ferroelect., Freq. Control, 64, 374-390, doi:10.1109/TUFFC.2016.2619913, 2017. |
|
More Info
| |
|
1 Feb 2017
|
|
 |
|
|
Various clinical applications of high-intensity focused ultrasound have different requirements for the pressure levels and degree of nonlinear waveform distortion at the focus. The goal of this paper is to determine transducer design parameters that produce either a specified shock amplitude in the focal waveform or specified peak pressures while still maintaining quasi-linear conditions at the focus. Multiparametric nonlinear modeling based on the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation with an equivalent source boundary condition was employed. Peak pressures, shock amplitudes at the focus, and corresponding source outputs were determined for different transducer geometries and levels of nonlinear distortion. The results are presented in terms of the parameters of an equivalent single-element spherically shaped transducer. The accuracy of the method and its applicability to cases of strongly focused transducers were validated by comparing the KZK modeling data with measurements and nonlinear full diffraction simulations for a single-element source and arrays with 7 and 256 elements. The results provide look-up data for evaluating nonlinear distortions at the focus of existing therapeutic systems as well as for guiding the design of new transducers that generate specified nonlinear fields.
|
|
 |
|
Release of cell-free microRNA tumor biomarkers in the blood circulation with pulsed focused ultrasound: A noninvasive, anatomically localized, molecular liquid biopsy Chevillet, J.R., T.D. Khokhlova, M.D. Giraldez, G.R. Schade, F. Starr, Y.-N. Wang, E.N. Gallichotte, K. Wang, J.H. Hwang, and M. Tewari, "Release of cell-free microRNA tumor biomarkers in the blood circulation with pulsed focused ultrasound: A noninvasive, anatomically localized, molecular liquid biopsy," Radiology, EOR, doi:10.1148/radiol.2016160024, 2016. |
|
More Info
| |
|
1 Nov 2016
|
|
 |
|
|
The purpose is to compare the abilities of three pulsed focused ultrasound regimes (that cause tissue liquefaction, permeabilization, or mild heating) to release tumor-derived microRNA into the circulation in vivo and to evaluate release dynamics. Mechanical tumor tissue disruption with pulsed focused ultrasound–induced bubble activity significantly increases the plasma abundance of tumor-derived microRNA rapidly after treatment.
|
|
 |
|
Design of HIFU transducers for generating specific nonlinear ultrasound fields Rosnitskiy, P.B., P.V. Yuldashev, O.A. Sapozhnikov, A. Maxwell, W. Kreider, M.R. Bailey, "Design of HIFU transducers for generating specific nonlinear ultrasound fields," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, doi:10.1109/TUFFC.2016.2619913, 2016. |
|
More Info
| |
|
20 Oct 2016
|
|
 |
|
|
Various clinical applications of high intensity focused ultrasound (HIFU) have different requirements for the pressure levels and degree of nonlinear waveform distortion at the focus. The goal of this work was to determine transducer design parameters that produce either a specified shock amplitude in the focal waveform or specified peak pressures while still maintaining quasilinear conditions at the focus. Multiparametric nonlinear modeling based on the KZK equation with an equivalent source boundary condition was employed. Peak pressures, shock amplitudes at the focus, and corresponding source outputs were determined for different transducer geometries and levels of nonlinear distortion. Results are presented in terms of the parameters of an equivalent single-element, spherically shaped transducer. The accuracy of the method and its applicability to cases of strongly focused transducers were validated by comparing the KZK modeling data with measurements and nonlinear full-diffraction simulations for a single-element source and arrays with 7 and 256 elements. The results provide look-up data for evaluating nonlinear distortions at the focus of existing therapeutic systems as well as for guiding the design of new transducers that generate specified nonlinear fields.
|
|
 |
|
Histotripsy liquefaction of large hematomas Khokhlova, T.D., W.L. Monsky, Y.A. Haider, A.D. Maxwell, Y.-N. Wang, and T.J. Matula, "Histotripsy liquefaction of large hematomas," Ultrasound Med. Biol., 42, 1491-1498, doi:10.1016/j.ultrasmedbio.2016.01.020, 2016. |
|
More Info
| |
|
1 Jul 2016
|
|
 |
|
|
Intra- and extra-muscular hematomas result from repetitive injury as well as sharp and blunt limb trauma. The clinical consequences can be serious, including debilitating pain and functional deficit. There are currently no short-term treatment options for large hematomas, only lengthy conservative treatment. The goal of this work was to evaluate the feasibility of a high intensity focused ultrasound (HIFU)-based technique, termed histotripsy, for rapid (within a clinically relevant timeframe of 1520 min) liquefaction of large volume (up to 20 mL) extra-vascular hematomas for subsequent fine-needle aspiration. Experiments were performed using in vitro extravascular hematoma phantomsfresh bovine blood poured into 50 mL molds and allowed to clot. The resulting phantoms were treated by boiling histotripsy (BH), cavitation histotripsy (CH) or a combination in a degassed water tank under ultrasound guidance. Two different transducers operating at 1 MHz and 1.5 MHz with f-number = 1 were used. The liquefied lysate was aspirated and analyzed by histology and sized in a Coulter Counter. The peak instantaneous power to achieve BH was lower than (at 1.5 MHz) or equal to (at 1 MHz) that which was required to initiate CH. Under the same exposure duration, BH-induced cavities were one and a half to two times larger than the CH-induced cavities, but the CH-induced cavities were more regularly shaped, facilitating easier aspiration. The lysates contained a small amount of debris larger than 70 μm, and 99% of particulates were smaller than 10 μm. A combination treatment of BH (for initial debulking) and CH (for liquefaction of small residual fragments) yielded 20 mL of lysate within 17.5 minutes of treatment and was found to be most optimal for liquefaction of large extravascular hematomas.
|
|
 |
|
Design of HIFU transducers to generate specific nonlinear ultrasound fields Khokhlova, V.A., P.V. Yuldashev, P.B. Rosnitskiy, A.D. Maxwell, W. Kreider, M.R. Bailey, and O.A. Sapozhnikov, "Design of HIFU transducers to generate specific nonlinear ultrasound fields," Phys. Proced., 87, 132-138, doi:10.1016/j.phpro.2016.12.020, 2016. |
|
More Info
| |
|
1 May 2016
|
|
 |
|
|
Various clinical applications of high intensity focused ultrasound (HIFU) have different requirements on the pressure level and degree of nonlinear waveform distortion at the focus. Applications that utilize nonlinear waves with developed shocks are of growing interest, for example, for mechanical disintegration as well as for accelerated thermal ablation of tissue. In this work, an inverse problem of determining transducer parameters to enable formation of shocks with desired amplitude at the focus is solved. The solution was obtained by performing multiple direct simulations of the parabolic KhokhlovZabolotskayaKuznetsov (KZK) equation for various parameters of the source. It is shown that results obtained within the parabolic approximation can be used to describe the focal region of single element spherical sources as well as complex transducer arrays. It is also demonstrated that the focal pressure level at which fully developed shocks are formed mainly depends on the focusing angle of the source and only slightly depends on its aperture and operating frequency. Using the simulation results, a 256-element HIFU array operating at 1.5 MHz frequency was designed for a specific application of boiling-histotripsy that relies on the presence of 90100 MPa shocks at the focus. The size of the array elements and focusing angle of the array were chosen to satisfy technical limitations on the intensity at the array elements and desired shock amplitudes in the focal waveform. Focus steering capabilities of the array were analysed using an open-source T-Array software developed at Moscow State University.
|
|
 |
|
Investigation into the mechanisms of tissue atomization by high-intensity focused ultrasound Simon, J.C., O.A. Sapzhnikov, Y.-N. Wang, V.A. Khokhlova, L.A. Crum, and M.R. Bailey, "Investigation into the mechanisms of tissue atomization by high-intensity focused ultrasound," Ultrasound Med. Biol., 41, 1372-1385, doi:10.1016/j.ultrasmedbio.2014.12.022, 2015. |
|
More Info
| |
|
1 May 2015
|
|
 |
|
|
Ultrasonic atomization, or the emission of a fog of droplets, was recently proposed to explain tissue fractionation in boiling histotripsy. However, even though liquid atomization has been studied extensively, the mechanisms underlying tissue atomization remain unclear. In the work described here, high-speed photography and overpressure were used to evaluate the role of bubbles in tissue atomization. As static pressure increased, the degree of fractionation decreased, and the ex vivo tissue became thermally denatured. The effect of surface wetness on atomization was also evaluated in vivo and in tissue-mimicking gels, where surface wetness was found to enhance atomization by forming surface instabilities that augment cavitation. In addition, experimental results indicated that wetting collagenous tissues, such as the liver capsule, allowed atomization to breach such barriers. These results highlight the importance of bubbles and surface instabilities in atomization and could be used to enhance boiling histotripsy for transition to clinical use.
|
|
 |
|
Ultrasonic atomization of liquids in drop-chain acoustic fountains Simon, J.C., O.A. Sapozhnikov, V.A. Khokhlova, and L.A. Crum, "Ultrasonic atomization of liquids in drop-chain acoustic fountains," J. Fluid Mech., 766, 129-146, doi:10.1017/jfm.2015.11, 2015. |
|
More Info
| |
|
1 Mar 2015
|
|
 |
|
|
When focused ultrasound waves of moderate intensity in liquid encounter an air interface, a chain of drops emerges from the liquid surface to form what is known as a drop-chain fountain. Atomization, or the emission of micro-droplets, occurs when the acoustic intensity exceeds a liquid-dependent threshold. While the cavitation-wave hypothesis, which states that atomization arises from a combination of capillary-wave instabilities and cavitation bubble oscillations, is currently the most accepted theory of atomization, more data on the roles of cavitation, capillary waves, and even heat deposition or boiling would be valuable. In this paper, we experimentally test whether bubbles are a significant mechanism of atomization in drop-chain fountains. High-speed photography was used to observe the formation and atomization of drop-chain fountains composed of water and other liquids. For a range of ultrasonic frequencies and liquid sound speeds, it was found that the drop diameters approximately equalled the ultrasonic wavelengths. When water was exchanged for other liquids, it was observed that the atomization threshold increased with shear viscosity. Upon heating water, it was found that the time to commence atomization decreased with increasing temperature. Finally, water was atomized in an overpressure chamber where it was found that atomization was significantly diminished when the static pressure was increased. These results indicate that bubbles, generated by either acoustic cavitation or boiling, contribute significantly to atomization in the drop-chain fountain.
|
|
 |
|
Histotripsy methods in mechanical disintegration of tissue: Toward clinical applications Khokhlova, V.A., J.B. Fowlkes, W.W. Roberts, G.R. Schade, Z. Xu, T.D. Khokhlova, T.L. Hall, A.D. Maxwell, Y.-N. Wang, and C.A. Cain, "Histotripsy methods in mechanical disintegration of tissue: Toward clinical applications," Int. J. Hypertherm., 31, 145-162, doi:10.3109/02656736.2015.1007538, 2015. |
|
More Info
| |
|
1 Mar 2015
|
|
 |
|
|
In high intensity focused ultrasound (HIFU) therapy, an ultrasound beam is focused within the body to locally affect the targeted site without damaging intervening tissues. The most common HIFU regime is thermal ablation. Recently there has been increasing interest in generating purely mechanical lesions in tissue (histotripsy). This paper provides an overview of several studies on the development of histotripsy methods toward clinical applications. Two histotripsy approaches and examples of their applications are presented. In one approach, sequences of high-amplitude, short (microsecond-long), focused ultrasound pulses periodically produce dense, energetic bubble clouds that mechanically disintegrate tissue. In an alternative approach, longer (millisecond-long) pulses with shock fronts generate boiling bubbles and the interaction of shock fronts with the resulting vapour cavity causes tissue disintegration. Recent preclinical studies on histotripsy are reviewed for treating benign prostatic hyperplasia (BPH), liver and kidney tumours, kidney stone fragmentation, enhancing anti-tumour immune response, and tissue decellularisation for regenerative medicine applications. Potential clinical advantages of the histotripsy methods are discussed. Histotripsy methods can be used to mechanically ablate a wide variety of tissues, whilst selectivity sparing structures such as large vessels. Both ultrasound and MR imaging can be used for targeting and monitoring the treatment in real time. Although the two approaches utilise different mechanisms for tissue disintegration, both have many of the same advantages and offer a promising alternative method of non-invasive surgery.
|
|
 |
|
Ultrasound-guided tissue fractionation by high intensity focused ultrasound in an in vivo porcine liver model Khokhlova, T.D., Y.-N. Wang, J.C. Simon, B.W. Cunitz, F. Starr, M. Paun, L.A. Crum, M.R. Bailey, and V.A. Khokhlova, "Ultrasound-guided tissue fractionation by high intensity focused ultrasound in an in vivo porcine liver model," P. Natl. Acad. Sci. USA, 111, 8161-8166, doi:10.1073/pnas.1318355111, 2014. |
|
More Info
| |
|
3 Jun 2014
|
|
 |
|
|
The clinical use of high intensity focused ultrasound (HIFU) therapy for noninvasive tissue ablation has been recently gaining momentum. In HIFU, ultrasound energy from an extracorporeal source is focused within the body to ablate tissue at the focus while leaving the surrounding organs and tissues unaffected. Most HIFU therapies are designed to use heating effects resulting from the absorption of ultrasound by tissue to create a thermally coagulated treatment volume. Although this approach is often successful, it has its limitations, such as the heat sink effect caused by the presence of a large blood vessel near the treatment area or heating of the ribs in the transcostal applications. HIFU-induced bubbles provide an alternative means to destroy the target tissue by mechanical disruption or, at its extreme, local fractionation of tissue within the focal region. Here, we demonstrate the feasibility of a recently developed approach to HIFU-induced ultrasound-guided tissue fractionation in an in vivo pig model. In this approach, termed boiling histotripsy, a millimeter-sized boiling bubble is generated by ultrasound and further interacts with the ultrasound field to fractionate porcine liver tissue into subcellular debris without inducing further thermal effects. Tissue selectivity, demonstrated by boiling histotripsy, allows for the treatment of tissue immediately adjacent to major blood vessels and other connective tissue structures. Furthermore, boiling histotripsy would benefit the clinical applications, in which it is important to accelerate resorption or passage of the ablated tissue volume, diminish pressure on the surrounding organs that causes discomfort, or insert openings between tissues.
|
|
 |
|
Characterization of a multi-element clinical HIFU system using acoustic halography and nonlinear modeling Kreider, W., P. Yuldashev, O.A. Sapozhnikov, N. Farr, A. Partanen, M. Bailey, and V.A. Khokhlova, "Characterization of a multi-element clinical HIFU system using acoustic halography and nonlinear modeling," IEEE Trans. Ultrason. Ferr. Freq. Control, 60, 1683-1698, doi:10.1109/TUFFC.2013.2750, 2013. |
|
More Info
| |
|
1 Aug 2013
|
|
 |
|
|
High-intensity focused ultrasound (HIFU) is a treatment modality that relies on the delivery of acoustic energy to remote tissue sites to induce thermal and/or mechanical tissue ablation. To ensure the safety and efficacy of this medical technology, standard approaches are needed for accurately characterizing the acoustic pressures generated by clinical ultrasound sources under operating conditions. Characterization of HIFU fields is complicated by nonlinear wave propagation and the complexity of phased-array transducers. Previous work has described aspects of an approach that combines measurements and modeling, and here we demonstrate this approach for a clinical phased-array transducer. First, low amplitude hydrophone measurements were performed in water over a scan plane between the array and the focus. Second, these measurements were used to holographically reconstruct the surface vibrations of the transducer and to set a boundary condition for a 3-D acoustic propagation model. Finally, nonlinear simulations of the acoustic field were carried out over a range of source power levels. Simulation results were compared with pressure waveforms measured directly by hydrophone at both low and high power levels, demonstrating that details of the acoustic field, including shock formation, are quantitatively predicted.
|
|
 |
|
Histological and biochemical analysis of mechanical and thermal bioeffects in boiling histotripsy lesions induced by high intensity focused ultrasound Wang, Y.-N., T. Khokhlova, M. Bailey, J.H. Hwang, and V. Khokhlova, "Histological and biochemical analysis of mechanical and thermal bioeffects in boiling histotripsy lesions induced by high intensity focused ultrasound," Ultrasound Med. Biol., 39, 424-438, doi:10.1016/j.ultrasmedbio.2012.10.012, 2013. |
|
More Info
| |
|
1 Mar 2013
|
|
 |
|
|
Recent studies have shown that shockwave heating and millisecond boiling in high-intensity focused ultrasound fields can result in mechanical fractionation or emulsification of tissue, termed boiling histotripsy. Visual observations of the change in color and contents indicated that the degree of thermal damage in the emulsified lesions can be controlled by varying the parameters of the exposure. The goal of this work was to examine thermal and mechanical effects in boiling histotripsy lesions using histologic and biochemical analysis. The lesions were induced in ex vivo bovine heart and liver using a 2-MHz single-element transducer operating at duty factors of 0.0050.01, pulse durations of 5500 ms and in situ shock amplitude of 73 MPa. Mechanical and thermal damage to tissue was evaluated histologically using conventional staining techniques (hematoxylin and eosin, and nicotinamide adenine dinucleotide-diaphorase). Thermal effects were quantified by measuring denaturation of salt soluble proteins in the treated region. According to histologic analysis, the lesions that visually appeared as a liquid contained no cellular structures larger than a cell nucleus and had a sharp border of one to two cells. Both histologic and protein analysis showed that lesions obtained with short pulses (<10 ms) did not contain any thermal damage. Increasing the pulse duration resulted in an increase in thermal damage. However, both protein analysis and nicotinamide adenine dinucleotide-diaphorase staining showed less denaturation than visually observed as whitening of tissue. The number of high-intensity focused ultrasound pulses delivered per exposure did not change the lesion shape or the degree of thermal denaturation, whereas the size of the lesion showed a saturating behavior suggesting optimal exposure duration. This study confirmed that boiling histotripsy offers an effective, predictable way to non-invasively fractionate tissue into sub-cellular fragments with or without inducing thermal damage.
|
|
 |
|
Ultrasonic atomization of tissue and its role in tissue fractionation by high intensity focused ultrasound Simon, J.C., O.A. Sapozhnikov, V.A. Khokhlova, Y.-N. Wang, L.A. Crum, and M.R. Bailey, "Ultrasonic atomization of tissue and its role in tissue fractionation by high intensity focused ultrasound," Phys. Med. Biol. 57, 8061-8078, doi:10.1088/0031-9155/57/23/8061, 2012. |
|
More Info
| |
|
7 Dec 2012
|
|
 |
|
|
Atomization and fountain formation is a well-known phenomenon that occurs when a focused ultrasound wave in liquid encounters an air interface. High intensity focused ultrasound (HIFU) has been shown to fractionate a tissue into submicron-sized fragments in a process termed boiling histotripsy, wherein the focused ultrasound wave superheats the tissue at the focus, producing a millimetre-sized boiling or vapour bubble in several milliseconds. Yet the question of how this millimetre-sized boiling bubble creates submicron-sized tissue fragments remains. The hypothesis of this work is that the tissue can behave as a liquid such that it atomizes and forms a fountain within the vapour bubble produced in boiling histotripsy. We describe an experiment, in which a 2 MHz HIFU transducer (maximum in situ intensity of 24,000 W cm-2) was aligned with an airtissue interface meant to simulate the boiling bubble. Atomization and fountain formation was observed with high-speed photography and resulted in tissue erosion. Histological examination of the atomized tissue showed whole and fragmented cells and nuclei. Airliquid interfaces were also filmed. Our conclusion was that HIFU can fountain and atomize tissue. Although this process does not entirely mimic what was observed in liquids, it does explain many aspects of tissue fractionation in boiling histotripsy.
|
|
 |
|
Disintegration of tissue using high intensity focused ultrasound: Two approaches that utilize shock waves Maxwell, A., O. Sapozhnikov, M. Bailey, L. Crum, Z. Xu, B. Fowlkes, C. Cain, and V. Khokhlova, "Disintegration of tissue using high intensity focused ultrasound: Two approaches that utilize shock waves," Acoust. Today, 8, 24-37, doi:10.1121/1.4788649, 2012. |
|
More Info
| |
|
1 Oct 2012
|
|
 |
|
|
Surgery is moving more and more toward minimally-invasive procedures using laparoscopic approaches with instruments inserted through tiny incisions or catheters placed in blood vessels through puncture sites. These techniques minimize the risks to the patient such as bleeding complications or infection during surgery. Taken a step further, high-intensity focused ultrasound (HIFU) can provide a tool to accomplish many of the same procedures without any incision at all. This article discusses the acoustics of histotripsy including the processes of generation and focusing of intense ultrasound, the formation of cavitation clouds and rapid boiling in tissue, and the interactions of ultrasound shock waves with bubbles leading to tissue disintegration.
|
|
 |
|
Controlled tissue emulsification produced by high intensity focused ultrasound shock waves and millisecond boiling Khokhlova, T.D., M.S. Canney, V.A. Khokhlova, O.A. Sapozhnikov, L.A. Crum, and M.R. Bailey, "Controlled tissue emulsification produced by high intensity focused ultrasound shock waves and millisecond boiling," J. Acoust. Soc. Am., 130, 3498-3510, doi:10.1121/1.3626152, 2011. |
|
More Info
| |
|
1 Nov 2011
|
|
 |
|
|
In high intensity focused ultrasound (HIFU) applications, tissue may be thermally necrosed by heating, emulsified by cavitation, or, as was recently discovered, emulsified using repetitive millisecond boiling caused by shock wave heating. Here, this last approach was further investigated. Experiments were performed in transparent gels and ex vivo bovine heart tissue using 1, 2, and 3 MHz focused transducers and different pulsing schemes in which the pressure, duty factor, and pulse duration were varied. A previously developed derating procedure to determine in situ shock amplitudes and the time-to-boil was refined. Treatments were monitored using B-mode ultrasound. Both inertial cavitation and boiling were observed during exposures, but emulsification occurred only when shocks and boiling were present. Emulsified lesions without thermal denaturation were produced with shock amplitudes sufficient to induce boiling in less than 20 ms, duty factors of less than 0.02, and pulse lengths shorter than 30 ms. Higher duty factors or longer pulses produced varying degrees of thermal denaturation combined with mechanical emulsification. Larger lesions were obtained using lower ultrasound frequencies. The results show that shock wave heating and millisecond boiling is an effective and reliable way to emulsify tissue while monitoring the treatment with ultrasound.
|
|
 |
|
Shock-induced heating and millisecond boiling in gels and tissue due to high intensity focused ultrasound Canney, M.S., V.A. Khokhlova, O.V. Bessonova, M.R. Bailey, and L.A. Crum, "Shock-induced heating and millisecond boiling in gels and tissue due to high intensity focused ultrasound," Ultrasound Med Biol., 36, 250-267, 2010. |
|
More Info
| |
|
1 Feb 2010
|
|
 |
|
|
Nonlinear propagation causes high-intensity ultrasound waves to distort and generate higher harmonics, which are more readily absorbed and converted to heat than the fundamental frequency. Although such nonlinear effects have been investigated previously and found to not significantly alter high-intensity focused ultrasound (HIFU) treatments, two results reported here change this paradigm. One is that at clinically relevant intensity levels, HIFU waves not only become distorted but form shock waves in tissue. The other is that the generated shock waves heat the tissue to boiling in much less time than predicted for undistorted or weakly distorted waves.
In this study, a 2-MHz HIFU source operating at peak intensities up to 25,000 W/cm2 was used to heat transparent tissue-mimicking phantoms and ex vivo bovine liver samples. Initiation of boiling was detected using high-speed photography, a 20-MHz passive cavitation detector and fluctuation of the drive voltage at the HIFU source. The time to boil obtained experimentally was used to quantify heating rates and was compared with calculations using weak shock theory and the shock amplitudes obtained from nonlinear modeling and measurements with a fiber optic hydrophone. As observed experimentally and predicted by calculations, shocked focal waveforms produced boiling in as little as 3 ms and the time to initiate boiling was sensitive to small changes in HIFU output. Nonlinear heating as a result of shock waves is therefore important to HIFU, and clinicians should be aware of the potential for very rapid boiling because it alters treatments.
|
|
 |
|
Magnetic resonance imaging of boiling induced by high intensity focused ultrasound Khokhlova, T.D., M.S. Canney, D. Lee, K.I. Marro, L.A. Crum, V.A. Khokhlova, and M.R. Bailey, "Magnetic resonance imaging of boiling induced by high intensity focused ultrasound," J. Acoust. Soc. Am., 125, 2420-2431, 2009. |
|
More Info
| |
|
1 Apr 2009
|
|
 |
|
|
Both mechanically induced acoustic cavitation and thermally induced boiling can occur during high intensity focused ultrasound (HIFU) medical therapy. The goal was to monitor the temperature as boiling was approached using magnetic resonance imaging (MRI). Tissue phantoms were heated for 20 s in a 4.7-T magnet using a 2-MHz HIFU source with an aperture and radius of curvature of 44 mm. The peak focal pressure was 27.5 MPa with corresponding beam width of 0.5 mm. The temperature measured in a single MRI voxel by water proton resonance frequency shift attained a maximum value of only 73 degrees C after 7 s of continuous HIFU exposure when boiling started. Boiling was detected by visual observation, by appearance on the MR images, and by a marked change in the HIFU source power. Nonlinear modeling of the acoustic field combined with a heat transfer equation predicted 100 degrees C after 7 s of exposure. Averaging of the calculated temperature field over the volume of the MRI voxel (0.3 x 0.5 x 2 mm(3)) yielded a maximum of 73 degrees C that agreed with the MR thermometry measurement. These results have implications for the use of MRI-determined temperature values to guide treatments with clinical HIFU systems.
|
|
|
|
Media Coverage
|
 |
|
High-intensity sound waves may aid regenerative medicine Acoustical Society of America Newswise Researchers at the University of Washington have developed a way to use sound to create cellular scaffolding for tissue engineering, a unique approach that could help overcome one of regenerative medicine’s significant obstacles. |
|
30 Oct 2014
|
|
 |
 |
|
WashingtonRussian collaboration sends shock waves through focused ultrasound Newsletter of the Focused Ultrasound Foundation An alternative method of tissue fractionation boiling histotripsy has been developed in a unique collaboration between the University of Washington (UW) in Seattle and Moscow State University (MSU) in Russia. |
|
17 Apr 2014
|
|
 |
|
|